Motor Connecting Cables | |||
2YSLCY-JB/2YSLCYK-JB | 9YSLCY-JB | PENDANT CABLE |
Mineral insulated cables
Fluoropolymer-insulated Heating Cable up to 260 °C with Protective Braid Cu/Ni
Application
Vessels, piping, valves
Small components
Industrial areas
Rotor blades
Marble plates
Standard
DIN VDE 0253
Voltage Rating
750V
CABLE CONSTRUCTION
Heating conductor.
Insulation: Fluoropolymer.
Protective: Nickel-plated copper braid.
Mechanical and Thermal Properties
Maximum operating temperature: 260℃
Minimum installation temperature: -60℃
Minimum bending radius: 2.5xOD
Maximum output: 30 W/m
Nominal resistance of heating conductor: 8000 Ω/km
Cable Parameter
Nominal resistance |
APPROX. |
7APPROX. |
Temperature coefficient |
---|---|---|---|
1.95 (Cu 10mm²) |
7.11 |
157.0 |
4.3 |
2.90 (Cu 6mm²) |
5.99 |
104.9 |
4.3 |
4.40 (Cu 4mm²) |
4.73 |
69.8 |
4.3 |
7.20 (Cu 2.5mm²) |
3.89 |
48.3 |
4.3 |
10.0 |
3.62 |
40.6 |
4.3 |
11.7 (Cu 1.5mm²) |
3.53 |
37.6 |
4.3 |
15.0 |
3.20 |
33.6 |
4.3 |
25.0 |
3.15 |
31.1 |
3.0 |
31.5 |
3.55 |
39.6 |
1.6 |
50.0 |
3.15 |
31.3 |
1.6 |
65.0 |
3.04 |
28.6 |
1.6 |
80.0 |
3.32 |
34.5 |
0.9 |
100.0 |
3.11 |
31.0 |
0.9 |
157.0 |
3.10 |
31.2 |
0.45 |
180.0 |
2.84 |
25.8 |
0.45 |
200.0 |
2.98 |
28.2 |
0.45 |
260.0 |
2.87 |
26.3 |
0.45 |
280.0 |
2.76 |
24.3 |
0.38 |
328.0 |
3.13 |
30.6 |
0.18 |
360.0 |
2.71 |
23.7 |
0.45 |
430.0 |
2.96 |
27.6 |
0.18 |
480.0 |
2.94 |
26.8 |
0.18 |
600.0 |
2.80 |
24.9 |
0.18 |
800.0 |
2.69 |
23.2 |
0.18 |
1000.0 |
2.81 |
24.9 |
0.04 |
1470.0 |
2.64 |
22.6 |
0.04 |
1750.0 |
2.66 |
22.3 |
0.04 |
1900.0 |
2.84 |
25.6 |
0.40 |
2900.0 |
2.68 |
23.1 |
0.40 |
4000.0 |
2.61 |
21.9 |
0.40 |
4700.0 |
2.55 |
21.6 |
0.15 |
6000.0 |
2.49 |
20.6 |
0.20 |
7000.0 |
2.43 |
19.9 |
0.15 |
8000.0 |
2.41 |
19.7 |
0.15 |